Naím cílem je jednoznan pohoda naich host, kterou plná automatizace.
Loxone relay extension pro#
Nyní je v Hotelu Terrassenhof v provozu 24 Miniserver, co odráí nae nadení pro Loxone a automatizaci budov. With its fourteen 16A rated relays, it will switch even the heaviest loads with ease. Will still use the old extension as it still has working relays and digital input/output that drives. » Miniserver » Audioserver » AO Extension » Modbus Extension » Relay Extension » EnOcean Extension » Tree Extension. The Relay Extension is a true powerhouse. The installation requires a suitable enclosure to ensure protection against contact, water and dust. to Loxone English Thanks for all offers of help.

The installation must be carried out by a qualified technician in accordance with all applicable regulations. When selected, you will be notified via System Status or the Mailer if the device is no longer available or goes offline. 250VAC) ist die Extension bestens für Schaltaufgaben aller Art geeignet. Dank der leistungsstarken Relais (16A, max.
Loxone relay extension serial number#
Save into the Miniserver, in order to pair the Extension.Īfterwards the program must be loaded from the Miniserver to transfer the actual serial number of the Extension into the program. Die Loxone Relay Extension ist mit 14 potenzialfreien Relais ausgestattet. This can only be used if there is only one Extension of the same type. Symbol: loxone - loxone multi extension air loxone multi extension air. Specifies the serial number of the device.įor Extensions: Enter 'Auto' to automatically pair an extension with unknown serial number. This can be due to short-circuits, overloaded switching loads or too high an ambient temperature.

If the CPU temperature reaches a critical point, the outputs of the device are switched off. shows a distribution box that contains the following components: Miniserver, Extension, Dimmer, Relay. The Extension starts after switching on the power supply, and the status LED will flash orange after a short time when the connection to the Miniserver is established. The Smart Building uses Loxone for home control. For loads exceeding 12A, use a wire cross-section of 2.5mm².įor thermal reasons the total load rating must not exceed 48A (IEC) or 45A (UL). Make sure you provide a double pole isolator where your immersion. Clipped direct, 2.5mm is usually sufficient. Just a couple of notes for you, you may find that 4mm isn’t necessary depending on your cable routing and installation method. The Relay Extension is installed on a DIN rail in a suitable enclosure.Ĭonnect the power supply and Link communication to the Miniserver.Ĭonnect the loads to the relay terminals. I personally use a separate, fairly inexpensive, relay that loxone switches to power the immersion. The Link cable can for example be used to connect the DMX extension which controls DYDELL lamps.The Relay Extension features 14 dry contact relay outputs.ĭatasheet Relay Extension Table of Contents The Loxone Link cable allows the system to be extended with additional ports up to 30 extensions. With this module you can easily expand your installation with additional switch contacts. connect analogue control valves– LAN interface for programming, visualisation and checking network devices, such as TV, PV system – KNX interface for communication with KNX products. to connect 4 roller shutters (curtains) or 8 lighting circles – 8 digital inputs to connect push buttons or sensors such as window, door contacts and more – 4 analogue inputs to connect temperature sensors, humidity sensors – 4 analogue outputs to e.g. With a 24V power supply and some help from DYDELL or Loxone Partner, the Mini Server is ready to use right away. Many devices can be connected directly to the Mini Server with numerous inputs and outputs. The Loxone Mini Server is the wired central control system that organises, all tasks in and around your home.